UPD2450W-4SEI-DC24/UPD2450-4SEI
・24V spec, Ethernet light control type・Common to all colors
・RoHS-compliant
・Worldwide power supply
・Not compatible with the UHP/UKS Series
download manual(UPD2450W-4SEI)
検索
Type | UPD2450W-4SEI-DC24V | UPD2450W-4SEI | ||
---|---|---|---|---|
control channels | 4ch | |||
Output for LED device | PWM/Strobe 24VDC 45W(Max.)※1 | |||
Control method | Constant voltage PWM system / Strobe system ※2 | |||
PWM system | Output Voltage 24VDC typ. (fixed) PWM Frequency Approx. 170kHz Dimming Steps 256 step |
|||
Strobe system | Output voltage 24VDC(Fixed) ※3 Lighting activation Trigger signal to the main unit Lighting delay 5usec typ. Lighting time 10us~255us(1us step) 10us~2550us(10us step) 100us~25.5ms(100us step)※2 Lighting regularity Trigger interval should be 4 times longer than lighting time.(duty 25%) Trigger signal pulse Pulse width : More than 20us, less than lighting frequency Trigger polar signal Polarity reversible (All channels at once) ※2 |
|||
Installation method | Equipped to the machine fixing by M3 screw or DIN rail | |||
Input voltage | 24VDC(23V~25V) | 100~240VAC 50Hz/60Hz | ||
Input current | 2.1A Max※4 | 0.67A/0.36A typ※4 | ||
Power consumption | 50.4W typ※4 | 67VA/72VA typ※4 | ||
Inrush current | 55A/200usec typ. | 15A/30A typ.(Cold start) | ||
Power supply | 3p Terminal block | AC power code with grounded IEC C14 Type | ||
Protection from overcurrent | Fuse(3.15A) | Fuse(2.5A)※5 | ||
Operating environment | Temperature 0~40℃ Humidity 30~85%RH (non-condensing) Altitude 2000m (Max) Pollution degree Level 2 |
|||
Storage Temperature/Humidity | -15~65℃ / 20~85%RH (non-condensing) | |||
Cooling method | Forced cooling (side intake/side exhaust) | |||
Environmental regulation | RoHS | |||
CE Marking | EMC directive:EN61326-1、Low voltage directive:EN61010-1 | Dimming steps | 256 step | |
Dimming method | Manual Dial and push buttons indicated by 7 segment LED Remoto Ethernet (10BASE-T/100BASE-TX) |
|||
External control connector |
Ethernet RJ45 ※6 LED ON/OFF、ararm Europe type 6P terminal block ※7 |
|||
Method By signal from outer device (Polarity reversible) | ||||
Alarm |
Detection Output overcurrent Display/Output ・Alarm shown on the front panel, all LED turn off. ・Alarm signal will be output from the external control connector ・Checking the cause of alarm by sending alarm check command ※8 Deactivation method ・Turing off the power ・Deactivation command ※9 |
|||
Ethernet communication setting |
IP Address Fixed IP(Default setting : 192.168.1.10/24 Port : 50001) Communication method TCP/IP Setting TCP server ※10 Number of client connection 1 Initializing Reset operation returns to the initial value |
|||
Dimension | W178mm x H111mm x D83mm (exclude robber foots and projected parts) ※11 | |||
Weight | approx.1.2kg |
※1 The power consumption wattage should not exceed 45W.
※2 Switching can be controlled by Dip Switch(DSW).
※3 The light emission intensity is fixed. The over drive lighting is not functional.
※4 At the maximum output.
※5 It is equipped on the witching power supply.
※6 The ethernet connector is not enclosed in the package.
※7 Please use the connector enclosed in the package.
※8 The Automatic Alarming Function is not equipped.
※9 Deactivation by command is allowed only at the ethernet operation.
※10 The control side(PC, etc) should be TCP Client.
※11 Please see the outer dimension(page 18).
※12 The specification might be changed without notice as adding function or functional improvement.