Model number |
UHPS-2EI |
Input power |
DC24V±10% |
Current consumption |
0.5A |
Protective function |
Overcurrent detection. |
Control method |
Constant current control method |
Control channels |
2ch |
Lighting ON/OFF |
By external signal (polarity reversible) |
Applicable lighting |
U-Technology high-power spot lighting
However, for IR,a separate adapter (UHPS-IREXC) is required. |
Control method |
Output current |
500mA, 700mA, 1A Switchable (2ch collectively) (※1) |
Constant current method |
Constant current control using DC-DC converter |
Dimming Steps |
1000 step |
External control
connector |
Ethernet |
RJ45 |
LED ON/OFF、Alarm |
Europe type 6P terminal block |
Alarm |
Detection |
Output overcurrent、Internal anomaly |
Display/Output |
Alarm shown on the front panel, all LED turn off. |
Alarm signal will be output from the external control connector |
Checking the cause of alarm by sending alarm check command |
Clear alarm |
Turing off the power、Reset switch、Deactivation command (※2) |
Ethernet
communication
setting |
Interface |
Ethernet 10BASE-T / 100BASE-TX |
IP Address |
Fixed IP(Default setting : 192.168.1.10/24 Port : 50001) |
Communication format |
TCP/IP |
Setting |
TCP server (※3) |
Number of client
connection |
1 |
Initializing |
Reset operation returns to the initial value |
Operating environment |
Temperature |
0 ~ +40℃ |
Humidity |
20 ~ 85%RH (non-condensing) |
Altitude |
2000m(Max) |
Pollution degree |
Level 2 |
Protection classⅠ Installation categoryⅡ Indoor use only |
Storage Temperature/Humidity |
-15 ~ +85℃ / 20 ~ 85%RH (non-condensing) |
Environmental regulation |
EMC 2014/30/EU RoHS 2011/65/EU |
CE Marking |
EMC EN61000-6-2、EN61000-6-4 |
Installation method |
35mmDIN rail |
Dimension |
W50×H65×D60mm |
Weight |
approx.90g |
※1 Setting is required in setting mode.
※2 Deactivation by command is allowed only at the ethernet operation.
※3 The control side(PC, etc) should be TCP Client.
※4 The specification might be changed without notice as adding function or functional improvement.